1×32 mini Fiber Optic PLC Splitter
- Fiber Type:G652D or customize
- Splitter Type:1×2 or customize
- Brand Name: CFO
We offer several types of high-quality splitters. These products are designed for long-term reliability, superior performance, and a wide range of uses in fiber optics including optical transmission, long haul, subscriber loop, and fiber to the home, telecommunications, CATV, test equipment, optical fiber sensors, data communications and wide-area network.
Our optical splitters are designed for consistent performance, low optical loss, low polarization sensitivity, superior environmental and mechanical characteristics, and fast installation. They also enable more effective monitoring and management of fiber optical networks.
Features:
Applications:
Table1. 1XN PLC splitter(with connector)
Parameters | 1×2 | 1×4 | 1×8 | 1×16 | 1×32 | 1×64 |
Operating Wavelength (nm) | 1260~1650 | |||||
Insertion Loss (dB) | ≤4.3 | ≤7.5 | ≤11.0 | ≤14.0 | ≤17.0 | ≤21.0 |
Loss Uniformity (dB) | ≤0.6 | ≤0.6 | ≤0.8 | ≤1.2 | ≤1.5 | ≤1.8 |
PDL (dB) | ≤0.2 | ≤0.2 | ≤0.2 | ≤0.3 | ≤0.3 | ≤0.3 |
Return loss(dB) | UPC≥50dB;APC≥55dB | |||||
Directivity (dB) | ≥55 | |||||
Pigtail Length (m) | 1m or customer specified | |||||
Fiber Type | G657A or customer specified | |||||
Operation temperature(℃) | -40~85 | |||||
Note:
All measurements were done at room temperature. Above parameters all testing at 1310nm,1550nm wavelength, if it test at 1260~1300nm,1600~1650nm,then insertion loss would be add 0.3dB based on above parameters. |
Table2. 2XN PLC splitter(with connector)
Parameters | 2×2 | 2×4 | 2×8 | 2×16 | 2×32 | 2×64 |
Operating Wavelength (nm) | 1260~1650 | |||||
Insertion Loss (dB) | ≤4.5 | ≤8.0 | ≤11.7 | ≤14.7 | ≤17.9 | ≤21.2 |
Loss Uniformity (dB) | ≤0.8 | ≤1.0 | ≤1.0 | ≤1.5 | ≤2.0 | ≤2.5 |
PDL (dB) | ≤0.2 | ≤0.2 | ≤0.2 | ≤0.3 | ≤0.3 | ≤0.3 |
Return loss(dB) | UPC≥50dB;APC≥55dB | |||||
Directivity (dB) | ≥55 | |||||
Pigtail Length (m) | 1m or customer specified | |||||
Fiber Type | G657A or customer specified | |||||
Operation temperature(℃) | -40~85 | |||||